The National Association of
Certified Home Inspectors

Standards of Practice
Table of
Contents
1. Definitions and Scope.
2. Standards of Practice
2.1.
Roof
2.2. Exterior
2.3. Basement, Foundation, Crawlspace & Structure
2.4. Heating
2.5. Cooling
2.6. Plumbing
2.7. Electrical
2.8. Fireplace
2.9. Attic & Insulation
2.10. Doors, Windows & Interior
3. Limitations, Exceptions &
Exclusions
4. Glossary of Terms
1.
Definitions and Scope
1.1. A Home inspection is a
non-invasive visual examination of a residential dwelling, performed for a fee,
which is designed to identify observed material defects within specific
components of said dwelling. Components may include any combination of
mechanical, structural, electrical, plumbing, or other essential systems or
portions of the home, as identified and agreed to by the Client and Inspector,
prior to or during the inspection process.
I. A home inspection is intended
to assist in evaluation of the overall condition of the dwelling. The inspection
is based on observation of the visible and apparent condition of the structure
and its components on the date of the inspection and not the determination of
future conditions.
II. A home inspection will not
reveal every problem that exists or ever could exist, but only those material
defects observed on the day of the inspection.
1.2. A Material defect is a
problem with a residential real property or any portion of it that would have a
significant adverse impact on the value of the property or that involves an
unreasonable risk to people on the property. The fact that a structural element,
system or subsystem is near, at or beyond the end of the normal useful life of
such a structural element, system or subsystem is not by itself a material
defect.
1.3. An Inspection report shall
describe and identify in written format the inspected systems, structures, and
components of the dwelling and shall identify material defects observed.
Inspection reports may contain recommendations regarding conditions reported or
recommendations for correction, monitoring or further evaluation by
professionals.
2.
Standards of Practice
2.1. Roof
I. The
inspector shall inspect from ground level or eaves:
A. The
roof covering.
B. The gutters.
C. The downspouts.
D. The vents, flashings, skylights, chimney and other roof penetrations.
E. The general structure of the roof from the readily accessible panels, doors
or stairs.
II. The
inspector is not required to:
A.
Walk on any roof surface.
B. Predict the service life expectancy.
C. Inspect underground downspout diverter drainage pipes.
D. Remove snow, ice, debris or other conditions that prohibit the observation of
the roof surfaces.
E. Inspect antennae, lightning arresters, or similar attachments.
2.2. Exterior
I. The
inspector shall inspect:
A. The
flashing and trim.
B. All exterior doors, decks, stoops, steps, stairs, porches, railings, eaves,
soffits, fascias, grading, and walkways.
C. And report as in need of repair any spacings between intermediate balusters,
spindles, or rails for steps, stairways, balconies, and railings that permit the
passage of an object greater than four inches in diameter.
D. The vegetation, surface drainage and retaining walls when these are likely to
adversely affect the building.
E. And describe the exterior wall covering.
II. The
inspector is not required to:
A.
Inspect or operate screens, storm windows, shutters, awnings, fences,
outbuildings, or exterior accent lighting.
B. Inspect items, including window and door flashings, which are not visible or
readily accessible from the ground.
C. Inspect geological, geotechnical, or hydrological conditions.
D. Inspect recreational facilities.
E. Inspect seawalls, break-walls and docks.
F. Inspect erosion control and earth stabilization measures.
G. Inspect for safety type glass.
H. Inspect underground utilities.
I. Inspect underground items.
J. Inspect wells or springs.
K. Inspect solar systems.
L. Inspect swimming pools or spas.
M. Inspect septic systems or cesspools.
N. Inspect playground equipment.
O. Inspect sprinkler systems.
P. Inspect drain fields or drywells.
Q. Determine the integrity of the thermal window seals or damaged glass.
2.3. Basement, Foundation &
Crawlspace
I. The
inspector shall inspect:
A. The
basement.
B. The foundation
C. The crawlspace.
D. The visible structural components.
E. Any present conditions or indications of active water penetration by probing
a representative sampling of structural components where deterioration is
believed to be present or where clear indications of deterioration are present.
F. And report any general indications of foundation movement that are observed,
such as but not limited to sheetrock cracks, brick cracks, out-of-square door
frames or floor slopes.
II. The
inspector is not required to:
A.
Enter any crawlspaces that are not readily accessible or where entry could cause
damage or pose a hazard to the inspector in his or her opinion.
B. Move stored items or debris.
C. Operate sump pumps with inaccessible floats.
D. Identify size, spacing, span, location or adequacy of foundation bolting,
bracing, joists or support systems.
E. Provide any engineering or architectural service.
F. Report on the adequacy of any structural system or component.
2.4. Heating
I. The
inspector shall inspect:
A. The
heating system and describe the energy source and heating method using normal
operating controls.
B. And report as in need of repair electric furnaces which do not operate.
C. And report if inspector deemed the furnace inaccessible.
II. The
inspector is not required to:
A.
Inspect or evaluate interiors of flues or chimneys, fire chambers, the heat
exchanger, the humidifier or dehumidifier, the electronic air filter, solar
heating systems or fuel tanks.
B. Inspect underground fuel tanks.
C. Determine the uniformity, temperature, flow, balance, distribution, size,
capacity, BTU, or supply adequacy of the heating system.
D. Light pilot flames.
E. Activate heating, heat pump systems, or other heating systems when ambient
temperatures or other circumstances are not conducive to safe operation or may
damage the equipment.
F. Operate electronic thermostats.
G. Evaluate fuel quality.
2.5. Cooling
I. The
inspector shall inspect:
A. The central cooling equipment using normal
operating controls.
II. The
inspector is not required to:
A.
Determine the uniformity, temperature, flow, balance, distribution, size,
capacity, BTU, or supply adequacy of the cooling system.
B. Inspect window units, through-wall units, or electronic air filters.
C. Operate equipment or systems if exterior temperature is below 60 degrees
Fahrenheit or when other circumstances are not conducive to safe operation or
may damage the equipment.
D. Inspect or determine thermostat calibration, heat anticipation or automatic
setbacks or clocks.
E. Examine electrical current, coolant fluids or gasses, or coolant leakage.
2.6. Plumbing
I. The
inspector shall:
A.
Inspect the main water shut off valve.
B. Inspect the water heating equipment, including combustion air, venting,
connections, energy sources, seismic bracing, and verify the presence or absence
of temperature-pressure relief valves and/or Watts 210 valves.
C. Flush toilets.
D. Run water in sinks, tubs, and showers.
E. Inspect the interior water supply including all fixtures and faucets.
F. Inspect the drain, waste and vent systems, including all fixtures.
G. Describe any visible fuel storage systems.
H. Inspect the drainage sump pumps testing sumps with accessible floats.
I. Inspect and describe the water supply, drain, waste and main fuel shut-off
valves, as well as the location of the water main and main fuel shut-off valves.
J. Inspect and determine if the water supply is public or private.
K. Inspect and report as in need of repair deficiencies in the water supply by
viewing the functional flow in two fixtures operated simultaneously.
L. Inspect and report as in need of repair deficiencies in installation and
identification of hot and cold faucets.
M. Inspect and report as in need of repair mechanical drain-stops that are
missing or do not operate if installed in sinks, lavatories and tubs.
N. Inspect and report as in need of repair commodes that have cracks in the
ceramic material, are improperly mounted on the floor, leak, or have tank
components which do not operate.
II. The
inspector is not required to:
A.
Light pilot flames.
B. Determine the size, temperature, age, life expectancy or adequacy of the
water heater.
C. Inspect interiors of flues or chimneys, water softening or filtering systems,
well pumps or tanks, safety or shut-of valves, floor drains or sprinkler
systems.
D. Determine the exact flow rate, volume, pressure, temperature, or adequacy of
the water supply.
E. Determine the water quality or potability or the reliability of the water
supply or source.
F. Open closed plumbing access panels.
G. Inspect clothes washing machine connections.
H. Operate any main, branch or fixture valve except fixture faucets and hose
faucets attached to the building.
I. Test shower pans, tub and shower surrounds or enclosures for leakage.
J. Evaluate the compliance with local or state conservation or energy standards,
or the proper design or sizing of any water, waste or venting components,
fixtures or piping.
K. Determine the effectiveness of anti-siphon, back-flow prevention or
drain-stop devices.
L. Determine whether there are sufficient clean-outs for effective cleaning of
drains.
M. Evaluate gas, liquid propane or oil storage tanks.
N. Excavate or otherwise uncover the private sewage system or its components to
determine size, adequacy or efficiency.
O. Inspect water treatment systems or water filters.
P. Inspect pressure pumps or bladder tanks.
Q.
Evaluate time to obtain hot water at fixtures, or perform testing of any kind to
water heater elements.
R.
Evaluate or determine the adequacy of combustion air.
S.
Test, operate, open or close Watts 210 valves and/or TPR valves.
T.
Examine ancillary systems or components, such as, but not limited to, those
relating to solar water heating, hot water circulation.
2.7. Electrical
I. The
inspector shall inspect:
A. The
service line.
B. The meter box.
C. The main disconnect.
D. And determine the service amperage.
E. Panels, breakers and fuses.
F. The grounding.
G. The bonding.
H. A representative sampling of switches, receptacles, light fixtures, and test
all GFCI receptacles and GFCI circuit breakers observed and deemed to be GFCI's
during the inspection.
I. And
report the presence of solid conductor aluminum branch circuit wiring if readily
visible.
J. And report on any GFCI-tested receptacles in which power is not present,
polarity is incorrect, the receptacle is not grounded, is not secured to the
wall, the cover is not in place, the ground fault circuit interrupter devices
are not properly installed or do not operate properly, or evidence of arcing or
excessive heat is present.
K. The service entrance conductors and the
condition of their sheathing.
L. The ground fault circuit interrupters with a GFCI tester.
M. And describe the amperage rating of the service.
N. And report the absence of smoke detectors.
O. Service entrance cables and report as in need of repair deficiencies in the
integrity of the insulation, drip loop, or separation of conductors at
weatherheads and clearances.
II. The
inspector is not required to:
A.
Insert any tool, probe or device into the main or sub-panels.
B. Operate electrical systems that are shut down.
C. Remove panel covers or dead front covers if not readily accessible.
D. Operate over current protection devices.
E. Operate non-accessible smoke detectors.
F. Measure or determine the amperage or voltage of the main service if not
visibly labeled.
G. Inspect the alarm system and components.
H. Inspect the ancillary wiring.
I. Activate any electrical systems or branch circuits which are not energized.
J. Operate overload devices.
K. Inspect low voltage systems, electrical de-icing tapes, swimming pool wiring
or any time-controlled devices.
L. Verify the continuity of the connected service ground.
M. Inspect private or emergency electrical supply sources, including but not
limited to generators, windmills, photovoltaic solar collectors, or battery or
electrical storage facility.
N. Inspect spark or lightning arrestors.
O. Conduct drop voltage calculations.
P. Determine the accuracy of breaker labeling.
2.8. Fireplace
I. The
inspector shall inspect:
A. The
fireplace, and open and close the damper door if readily accessible and
operable.
B. Hearth extensions and other permanently installed components.
C. And report as in need of repair deficiencies in the lintel, hearth and
material surrounding the fireplace, including clearance from combustible
materials
II. The
inspector is not required to:
A.
Inspect the vent system.
B. Inspect the interior of the chimney or flue, fire doors or screens, seals or
mantels.
C. Determine the need for a chimney sweep.
D. Operate gas fireplace inserts.
E. Light pilot flames.
F. Determine the appropriateness of such installation.
G. Inspect automatic fuel feed devices.
H. Inspect combustion make up devices.
I. Inspect heat distribution assists whether gravity controlled or fan assisted.
J. Ignite or extinguish fires.
K. Determine draft characteristics.
L. Move fireplace inserts, stoves, or firebox contents.
M. Determine adequacy of draft, perform a smoke test or dismantle or remove any
component.
2.9. Attic, Ventilation &
Insulation
I. The
inspector shall inspect:
A. The
insulation in unfinished spaces.
B. The ventilation of attic spaces.
C. Mechanical ventilation systems.
D. And report on the general absence or lack of insulation.
II. The
inspector is not required to:
A.
Enter the attic or unfinished spaces that are not readily accessible or where
entry could cause damage or pose a safety hazard to the inspector in his or her
opinion.
B. To move or touch insulation.
C. To move or touch vapor retarders.
D. Break or otherwise damage the surface finish or weather seal on or around
access panels and covers.
E. Identify the composition or the exact R-value of insulation material.
F. Activate thermostatically operated fans.
G. Determine the types of materials used in insulation/wrapping of pipes, ducts,
jackets, boilers, and wiring.
2.10. Doors, Windows &
Interior
I. The
inspector shall:
A.
Open and close a representative number of doors and windows.
B. Inspect the walls, ceilings, steps, stairways, and railings.
C. Inspect garage doors and garage door openers by operating first by remote (if
available) and then by the installed automatic door control.
D. And report as in need of repair any installed electronic sensors that are not
operable or not installed at proper heights above the garage door.
E. And report as in need of repair any door locks or side ropes that have not
been removed or disabled when garage door opener is in use.
F. And report as in need of repair any windows that are obviously fogged or
display other evidence of broken seals.
II. The
inspector is not required to:
A.
Inspect paint, wallpaper, window treatments or finish treatments.
B. Inspect central vacuum systems.
C. Inspect safety glazing in locations subject to human impact.
D. Inspect security components.
E. Evaluate the fastening of countertops, cabinets, sink tops and fixtures, or
firewall compromises.
F. Move furniture, stored items, or any coverings like carpets or rugs in order
to inspect the concealed floor structure.
G. Move drop ceiling tiles.
H. Inspect or move any household appliances.
I. Inspect or operate equipment housed in the garage except as otherwise noted.
J. Verify or certify safe operation of any auto reverse or related safety
function of a garage door.
K. Operate or evaluate security bar release and opening mechanisms, whether
interior or exterior, including compliance with local, state, or federal
standards.
L. Operate any system, appliance or component that requires the use of special
keys, codes, combinations, or devices.
M. Operate or evaluate self-cleaning oven cycles or signal lights.
N. Determine leakage from microwave ovens.
O. Operate or examine any sauna, steam-jenny, kiln, toaster, ice-maker,
coffee-maker, can-opener, bread-warmer, blender, instant hot water dispenser, or
other small, ancillary devices.
P. Inspect elevators.
Q. Inspect remote controls.
R. Inspect appliances.
S. Inspect items not permanently installed.
T. Examine or operate any above-ground, movable, freestanding, or otherwise
non-permanently installed pool/spa or self-contained equipment.
U. Come into contact with any pool or spa water in order to determine the system
structure or components.
V. Determine the adequacy of spa jet water force or bubble effect.
W. Determine the structural integrity or leakage of a pool or spa.
3.
Limitations, Exceptions & Exclusions
3.1. Limitations:
I. An
inspection is not technically exhaustive.
II. An inspection will not identify concealed or latent defects.
III. An inspection will not deal with aesthetic concerns or what could be deemed
matters of taste, cosmetic, etc.
IV. An inspection will not determine the suitability of the property for any
use.
V. An inspection does not determine the market value of the property or its
marketability.
VI. An inspection does not determine the advisability or inadvisability of the
purchase of the inspected property.
VII. An inspection does not determine the life expectancy of the property or any
components or systems therein.
VIII. An inspection does not include items not permanently installed.
IX. These Standards of Practice apply only to homes with four or fewer dwelling
units.
3.2. Exclusions:
I. The
inspectors are not required to determine:
A.
Property boundary lines or encroachments.
B. The condition of any component or system that is not readily accessible.
C. The service life expectancy of any component or system.
D. The size, capacity, BTU, performance, or efficiency of any component or
system.
E. The cause or reason of any condition.
F. The cause for the need of repair or replacement of any system or component.
G. Future conditions.
H. The compliance with codes or regulations.
I. The presence of evidence of rodents, animals or insects.
J. The presence of mold, mildew or fungus.
K. The presence of air-borne hazards.
L. The presence of birds.
M. The presence of other flora or fauna.
N. The air quality.
O. The existence of asbestos.
P. The existence of environmental hazards.
Q. The existence of electro-magnetic fields.
R. The presence of hazardous materials including, but not limited to, the
presence of lead in paint.
S. Any hazardous waste conditions.
T. Any manufacturer recalls or conformance with manufacturer installation or any
information included in the consumer protection bulletin.
U. Operating costs of systems.
V. Replacement or repair cost estimates.
W. The acoustical properties of any systems.
X. Estimates of how much it will cost to run any given system.
II. The
inspectors are not required to operate:
A.
Any system that is shut down.
B.
Any system that does not function properly.
C.
Or evaluate low voltage electrical systems such as, but not limited to:
1. Phone lines.
2. Cable lines.
3. Antennae.
4. Lights.
5. Remote controls.
D. Any system that does not turn on with the use of normal operating controls.
E. Any shut off valve.
F. Any electrical disconnect or over current protection devices.
G. Any alarm systems.
H. Moisture meters, gas detectors or similar equipment.
III.
The inspectors are not required to:
A. Move any personal items or other obstructions, such
as, but not limited to:
1.
Throw rugs.
2. Furniture.
3. Floor or wall coverings.
4. Ceiling tiles
5. Window coverings.
6. Equipment.
7. Plants.
8. Ice.
9. Debris.
10. Snow.
11. Water.
12. Dirt.
13. Foliage.
14. Pets
B.
Dismantle, open, or uncover any system or component.
C. Enter or access any area which may, in the opinion of the inspector, to be
unsafe or risk personal safety.
D. Enter crawlspaces or other areas that are unsafe or not readily accessible.
E. Inspect underground items such as, but not limited to, underground storage
tanks or other indications of their presence, whether abandoned or actively
used.
F. Do anything which, in the inspector's opinion, is likely to be unsafe or
dangerous to the inspector or others or damage property, such as, but not
limited to, walking on roof surfaces, climbing ladders, entering attic spaces or
negotiating with dogs.
G. Inspect decorative items.
H. Inspect common elements or areas in multi-unit housing.
I. Inspect intercoms, speaker systems, radio-controlled, security devices or
lawn irrigation systems.
J. Offer guarantees or warranties.
K. Offer or perform any engineering services.
L. Offer or perform any trade or professional service other than home
inspection.
M. Research the history of the property, report on its potential for alteration,
modification, extendibility, or its suitability for a specific or proposed use
for occupancy.
N. Determine the age of construction or installation of any system structure, or
component of a building, or differentiate between original construction or
subsequent additions, improvements, renovations or replacements thereto.
O. Determine the insurability of a property.
4.
Glossary of Terms
4.1. Accessible: Can be
approached or entered by the inspector safely, without difficulty, fear or
danger.
4.2. Activate: To turn on, supply
power, or enable systems, equipment, or devices to become active by normal
operating controls. Examples include turning on the gas or water supply valves
to the fixtures and appliances and activating electrical breakers or fuses.
4.3. Adversely Affect:
Constitute, or potentially constitute, a negative or destructive impact.
4.4. Alarm System: Warning
devices, installed or free-standing, including but not limited to: Carbon
monoxide detectors, flue gas and other spillage detectors, security equipment,
ejector pumps and smoke alarms.
4.5. Appliance: A household
device operated by use of electricity or gas. Not included in this definition
are components covered under central heating, central cooling or plumbing.
4.6. Architectural Service: Any
practice involving the art and science of building design for construction of
any structure or grouping of structures and the use of space within and
surrounding the structures or the design, design development, preparation of
construction contract documents, and administration of the construction
contract.
4.7. Component: A permanently
installed or attached fixture, element or part of a system.
4.8. Condition: The visible and
conspicuous state of being of an object.
4.9. Crawlspace: The area within
the confines of the foundation and between the ground and the underside of the
lowest floor structural component.
4.10. Decorative: Ornamental; not
required for the operation of essential systems and components of a home.
4.11. Describe: Report in writing
a system or component by its type, or other observed characteristics, to
distinguish it from other components used for the same purpose.
4.12. Determine: To arrive at an
opinion or conclusion pursuant to examination.
4.13. Dismantle: To open, take
apart or remove any component, device or piece that would not typically be
opened, taken apart or removed by an ordinary occupant.
4.14. Engineering Service: Any
professional service or creative work requiring engineering education, training,
and experience and the application of special knowledge of the mathematical,
physical and engineering sciences to such professional service or creative work
as consultation, investigation, evaluation, planning, design and supervision of
construction for the purpose of assuring compliance with the specifications and
design, in conjunction with structures, buildings, machines, equipment, works or
processes.
4.15. Enter: To go into an area
to observe all visible components.
4.16. Evaluate: To assess the
systems, structures or components of a dwelling.
4.17. Examine: To visually look.
See Inspect.
4.18. Foundation: The base upon
which the structure or wall rests; usually masonry, concrete, or stone, and
generally partially underground.
4.19. Function: The action for
which an item, component, or system is specially fitted or used or for which an
item, component or system exists; to be in action or perform a task.
4.20. Functional: Performing, or
able to perform, a function.
4.21. Home Inspection: The
process by which an inspector visually examines the readily accessible systems
and components of a home and operates those systems and components utilizing
these Standards of Practice as a guideline.
4.22. Household Appliances:
Kitchen and laundry appliances, room air conditioners, and similar appliances.
4.23. Inspect: To visually look
at readily accessible systems and components safely, using normal operating
controls and accessing readily accessible panels and areas.
4.24. Inspected Property: The readily accessible areas of the buildings, site,
items, components, and systems included in the inspection.
4.25. Inspector: One who performs
a real estate inspection.
4.26. Installed: Attached or
connected such that the installed item requires tool for removal.
4.27. Material Defect: Refer to
section 1.2.
4.28. Normal Operating Controls:
Devices such as thermostats that would be operated by ordinary occupants which
require no specialized skill or knowledge.
4.29. Observe: To see through
visually directed attention.
4.30. Operate: To cause systems
to function or turn on with normal operating controls.
4.31. Readily Accessible: An item
or component is readily accessible if, in the judgment of the inspector, it is
capable of being safely observed without movement of obstacles, detachment or
disengagement of connecting or securing devices, or other unsafe or difficult
procedures to gain access.
4.32. Recreational Facilities:
Spas, saunas, steam baths, swimming pools, tennis courts, playground equipment,
and other exercise, entertainment or athletic facilities.
4.33. Report: A written
communication (possibly including digital images) of any material defects seen
during the inspection.
4.34. Representative Number: A
sufficient number to serve as a typical or characteristic example of the item(s)
inspected.
4.35. Safety Glazing: Tempered
glass, laminated glass, or rigid plastic.
4.36. Shut Down: Turned off,
unplugged, inactive, not in service, not operational, etc.
4.37. Structural Component: A
component which supports non-variable forces or weights (dead loads) and
variable forces or weights (live loads).
4.38. System: An assembly of
various components to function as a whole.
4.39. Technically Exhaustive: A
comprehensive and detailed examination beyond the scope of a real estate home
inspection which would involve or include, but would not be limited to:
dismantling, specialized knowledge or training, special equipment, measurements,
calculations, testing, research, analysis or other means.
4.40. Unsafe: A condition in a
readily accessible, installed system or component which is judged to be a
significant risk of personal injury during normal, day-to-day use. The risk may
be due to damage, deterioration, improper installation or a change in accepted
residential construction standards.
4.41. Verify: To confirm or